Sign In | Join Free | My burrillandco.com
Home > pH ORP Controller >

Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment from wholesalers
     
    Buy cheap Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment from wholesalers
    • Buy cheap Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment from wholesalers
    • Buy cheap Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment from wholesalers
    • Buy cheap Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment from wholesalers
    • Buy cheap Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment from wholesalers
    • Buy cheap Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment from wholesalers
    • Buy cheap Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment from wholesalers

    Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : APX2-PD
    Certification : ISO, CE
    Price : Negotiable
    Delivery Time : 1-30days
    • Product Details
    • Company Profile

    Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment


    Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment


    Daruifuno brand APX2-PD dual-channel controller usually supports simultaneous connection of one analog pH electrode and one analog ORP (oxidation-reduction potential) electrode, or two analog pH sensors and two analog ORP sensors. The pH value and oxidation-reduction potential (mV value) of the solution are collected respectively. The internal analog circuit converts the electrode signal into a standard voltage signal, amplifies and filters it, and then the microprocessor of the controller performs numerical processing and judgment, thereby outputting a relay control signal or an analog current (such as 4-20mA) signal.
    pH channel: measures pH (0-14) and controls acid/base dosing.
    ORP channel: measures oxidation-reduction potential (±2000mV) for disinfection (such as chlorination) or dechlorination.
    The electrode is connected to the controller terminal; the controller relay output is connected to the dosing pump, alarm or cleaning device; the control logic, calibration, cleaning cycle, etc. can be set through the menu; regular calibration and data viewing are supported.


    Product Parameters


    ModelAPX2-PD-AAPX2-PD-D
    Measuring Objects2 measurement channel inputs, pH or ORP can be selected arbitrarily
    PrinciplePHGlass pH electrode (hydrogen ion concentration index)
    ORPPlatinum or gold electrodes (redox potential)
    Display RangePH: 0~14pH ORP: ± 2000mV Temp: -10~150℃
    ResolutionPH: 0.01pH ORP: 1mV TEMP: 0.1℃
    Accuracy0.1% of the measuring range or ±0.02pH / ±2mV, take the larger one
    Stability0.05% of measuring range every 24 hours without accumulation
    RepeatabilityBetter than 0.1% of measuring range
    Temp. CompensationAutomatic or manual (NTC10K/PT1000)
    Relay OutputTwo SPST relays, Max. load 3A/250VAC, set high/low alarm, temp. or clean control
    Digital CommunicationA two-wire RS485 interface, Modbus RTU and JSON
    Current OutputTwo 0/4~20mA current Max. load 1000Ω
    Time DisplayYear/month/date hour/minute/second
    Historical DataRecord 10000 historical data and the last 100 calibration maintenance data
    Valuation Object*Built-in matrix (equivalent to residual chlorine) 0~2.5mg/L
    Support user-defined (20x20 matrix)
    Linear correspondence (water sample stability)
    Display128*64 3.2-inch graphic dot matrix LCD
    Calibration MethodPH: 3 points ORP: 2 points, calibration points can be set freely
    MaterialEnhanced ABS Protection Grade: IP66
    Power SupplyAC: 100~240V 50/60HzDC: 18~36V
    Dimension144*144*120mm (Hole size 138*138mm)
    Work Temperature0~60℃, RH<95%, non-condensing
    Storage Temperature-20~70℃, RH<55%, non-condensing
    InstallationWall mounting, pipe clamp, panel

    ​Advantages and features

    • Dual-channel input: supports simultaneous connection of two electrodes (pH+pH, ORP+ORP, or pH+ORP) monitors pH and ORP at the same time, improves efficiency and saves installation space
    • Dual-channel relay output: can set high/low alarm, dosing control and other functions
    • Analog signal output (4-20mA): provides 4-20mA output, which is convenient for docking with PLC and DCS systems
    • High-definition LCD display Real-time display of pH/ORP, electrode status, temperature, relay status, etc.
    • History recording function: stores measurement data and alarm records for easy traceability
    • Electronic clock: provides timestamp, cooperates with data recording Built-in history record and electronic clock, you can query the time of key events
    • Automatic cleaning control: provides cleaning relay output, supports timing or conditional trigger cleaning function to extend electrode life
    • Multiple calibration methods: supports 1-point, 2-point or multi-point calibration to improve accuracy
    • Two Channels are isolated from each other
    • Each channel can be connected to an independent temp. system.
    • When pH, ORP and temp. are tested at the same time, the algorithm inside the meter can simultaneously evaluate the disinfection ability and display pH, ORP, temp. and chlorine values.
    • Meet pH/ORP monitoring, dosing control, and data signal remote transmission at the same time.
    • Menu-based operation Multi-language support, user-friendly interface, simple operation

    Daruifuno PH ORP controller APX2-PD history record and electronic clock function1. History recording function
    1.Store measurement data, alarm events, etc.
    Recording interval can be set (such as every 10 minutes)
    2. Electronic clock function
    Real-time clock module to ensure accurate event recording time


    Daruifuno PH ORP controller APX2-PD two-way relay control dosing principle
    Set the pH upper/lower limit. When the set value is exceeded, the relay will be activated.
    Example: pH > 9, start the acid dosing pump;
    pH < 6, start the alkali dosing pump;
    You can set the hysteresis interval to avoid frequent switching.


    Daruifuno PH ORP controller APX2-PD automatic cleaning control principle

    The cleaning relay can be set to start at a fixed time (such as every 24 hours); the flushing time setting
    starts the solenoid valve or water pump to clean the electrode
    avoids measurement errors caused by adhesion on the electrode surface.


    Daruifuno PH ORP controller APX2-PD pH and ORP calibration method
    1. pH calibration:
    Use standard buffer: pH 4.01, 7.00, 10.01, PH ORP controller produced by our company Daruifuno, the calibration point can be set freely.
    Single point calibration: Use pH 7.00 liquid to calibrate the zero point.
    Two-point calibration: pH 7.00 and 4.00 or 10.00, calibrate the zero point and slope.
    The controller guides the operation, automatically determines stability and stores.
    2. ORP calibration:
    Use standard buffer, such as +220mV or +470mV.
    The calibration process is simple, usually a single point is sufficient.


    Daruifuno PH ORP controller APX2-PD controller installation methodInstallation method:
    Panel installation (opening installation, IP66 protection panel)
    Wall installation (adaptive protection shell)
    Pipeline installation
    Installation environment:
    Avoid direct sunlight, high temperature and high humidity;
    Cables are routed separately to avoid sharing the same wiring trough with power lines;


    Aplication:
    ◇ Surface water
    ◇ Source water
    ◇ Aquaculture waters
    ◇ Landscape water
    ◇ Import of the waterworks

    ◇ Water treatment monitoring

    ◇ Drinking water,

    ◇ Groundwater, swimming pool

    ◇Industrial process monitoring and dosing control management

    ◇Chemical, petroleum, paper, food and medicine, electroplating, PCB manufacturing, etc.
    ◇ Municipal/industrial water treatment

    ◇ Circulating cooling water monitoring

    ◇ Electroplating/chemical liquid control

    ◇ Food and beverage production line
    ◇ Acid-base neutralization reaction tank control



    Quality Dule Channels Analog PH And ORP Controller With RS485 For Industrial Wastewater Treatment for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)