Sign In | Join Free | My burrillandco.com
Home > Turbidity Analyzer >

IP66 RS485 Laser Turbidity Transmitter For Wastewater Automatic Control

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap IP66 RS485 Laser Turbidity Transmitter For Wastewater Automatic Control from wholesalers
     
    Buy cheap IP66 RS485 Laser Turbidity Transmitter For Wastewater Automatic Control from wholesalers
    • Buy cheap IP66 RS485 Laser Turbidity Transmitter For Wastewater Automatic Control from wholesalers
    • Buy cheap IP66 RS485 Laser Turbidity Transmitter For Wastewater Automatic Control from wholesalers
    • Buy cheap IP66 RS485 Laser Turbidity Transmitter For Wastewater Automatic Control from wholesalers

    IP66 RS485 Laser Turbidity Transmitter For Wastewater Automatic Control

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : DUC2-LTU-H-D
    Certification : CE, ISO
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 10000 Sets per Month
    Delivery Time : 5-25 days
    • Product Details
    • Company Profile

    IP66 RS485 Laser Turbidity Transmitter For Wastewater Automatic Control


    IP66 RS485 Laser Turbidity Transmitter For Wastewater Automatic Control


    Turbidity varies widely and is typically measured from 0 to 5,000 ntu. Typical bottled drinking water is measured in single digits in ntu. Turbid water usually contains more than 1,000 ntu.


    While turbidity itself is usually not regulated, it is indicative of the overall cleanliness of the water and may indicate the presence of suspended contaminants. This field-friendly measurement indicates the presence of multiple contaminants that stain the sample. Turbidity measurements from different locations in the treatment stream can help track improved water quality as the water moves throughout the treatment process.

    Specification:

    ModelDUC2-LTU-H-D
    Software VersionDRFN TU Analysis software V1.0
    Sensor InputCompatible with all DRFN's TU Digital Sensors
    Display Range0.001NTU~4000NTU
    Resolution0.001 NTU
    Relay Control2 settable SPST relays with a maximum load of 3A/250VAC
    Analog Current Output2 settable 0/4~20mA current outputs with a maximum load 1000Ω
    Communication MethodTwo-wire RS485 interface; MODBUS RTU; support JSON text data format
    OTA——
    Display Screen

    128*64 black-and-white graphic lattice LCD
    adjustable backlight mode
    adjustable display rate

    Configuration InformationPower off protection, parameters are retained indefinitely
    Time/Data Record

    Year/month/day/hour/min/second, record 14000 historical data
    record interval can be set between 1~999 minutes

    Maintenance RecordsLast 100 times
    Protection LevelIP66
    Operating Environment0~60℃,RH<95% ( no condensation)
    Storage Environment-20~70℃,RH<55% ( no condensation, precision instruments)
    Shell MaterialEnhanced ABS
    Dimension144*144*120 mm
    Mounting MethodWall mounting, pipe clamping, panel installation (hole size 138*138 mm)
    Electrical InterfaceThe back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm
    Power supply

    18~36VDC

    Power ConsumptionAbout 12W
    Cleaning SystemMax.24W
    WeightAbout 800g

    Please click the user manual of RS485 turbidity controller here:

    DUC2 -LTU turbidity controller user manual.pdf

    Brief introduction:

    ● Compatible with all DRFN digital laser turbidity sensors;
    ● Separately have a list of controller and sensor settings for quick and detailed parameter setting;
    ● The working status of the sensor can be queried, including reading the serial number;
    ● Support a variety of installation methods;
    ● Time and historical data recording function;
    ● 3.2-inch large LCD screen;
    ● User-friendly Chinese and English language interface;
    ● Password can be set to prevent misoperation;
    ● 2 SPST multi-function and settable relays;
    ● Two 0/4~20mA active current loop outputs;
    ● RS485 interface, Modbus RTU communication protocol;
    ● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;

    IP66 RS485 Laser Turbidity Transmitter For Wastewater Automatic Control
    Aplication:

    ◇ Pure water
    ◇ Ultra-pure water
    ◇ Waterworks
    ◇ Secondary water supply project
    ◇ Swimming pool water testing


    FAQ

    Q1. Does the conductivity controller operation interface support customization?
    Yes, our conductivity controller operation interface can be tailored to customers' needs.

    Q2. Can customer's logo be added to the controller system and cover?
    Of course, we aid OEM offerings for customers. Both the boot interface and the controller shell may be delivered to the customer's logo, however there may be a minimal order amount requirement.

    Q3. How long is the warranty period?

    The company guarantees the instrument for one year (12 months) from the date of shippment, and the consumables and wearing parts in the equipment are not covered by the warranty.


    Q4. Does the lazer turbidity controller have an ambient temperature alarm function?
    Our turbidity controller has ambient temperature alarm function.