Sign In | Join Free | My burrillandco.com
Home > Conductivity Analyzer >

TDS Salinity Conductivity Analyzer

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap TDS Salinity Conductivity Analyzer from wholesalers
     
    Buy cheap TDS Salinity Conductivity Analyzer from wholesalers
    • Buy cheap TDS Salinity Conductivity Analyzer from wholesalers
    • Buy cheap TDS Salinity Conductivity Analyzer from wholesalers
    • Buy cheap TDS Salinity Conductivity Analyzer from wholesalers
    • Buy cheap TDS Salinity Conductivity Analyzer from wholesalers

    TDS Salinity Conductivity Analyzer

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : AEC2-H3D
    Certification : CE
    Price : Negotiable
    • Product Details
    • Company Profile

    TDS Salinity Conductivity Analyzer


    TDS Salinity Conductivity Analyzer 18~36V For Industrial Wastewater 800g

    Conductivity is the reciprocal of resistivity, reflecting the amount of salt in the water, and is a very important indicator of water quality.


    Conductivity analyzers can be divided into electrode type and electromagnetic induction type according to their structure. The AEC2-H3D series controllers uses electrode measurement method, can be used in various conductivity monitoring and control occasions.





    Advantages Of The TDS Salinity Conductivity Analyzer

    Smart Controller

    • The EC controller can be connected to different conductivity sensors to achieve different measurement ranges.
    • DRFN’s conductivity analyzer is equipped with 2 settable SPST relays, can make different settings.
    • The instrument has a two-wire RS485 interface and supports Modbus RTU communication.
    • The meter has time and historical recording function. 14000 historical data can be recorded, and the recording interval can be set between 1 and 999 minutes.


    Intuitive interface and simple operation

    • 128*64 large graphic dot matrix LCD screen, English or chinese language, adjustable backlight and display rate.
    • The shortcut keys help you to carry out daily necessary maintenance without entering the menu.
    • Menu password can be set to facilitate hierarchical management.


    Practical instrument

    • The protection grade is IP66, and the material of the meter is enhanced ABS, rugged and can be used outdoors.



    Applications Of The TDS Salinity Conductivity Analyzer

    ● Power plant-water treatment;

    ● Water plants and sewage plants-wastewater treatment;

    ● Papermaking-production process/wastewater treatment;

    ● Chemical oil refining-production process/wastewater treatment;

    ● Metallurgy and mining-production process/wastewater treatment;

    ● Food and beverage-production process/wastewater treatment;

    ● Semiconductor-production process/wastewater treatment/high-purity water production.

    Technical Parameters

    Product Name

    TDS Salinity Conductivity Analyzer

    Product Model

    AEC2-H3D

    Software Version

    DRFN conductivity Analysis software V1.0

    Conductivity Measuring Range

    0.00~200.00 mS/cm, full range automatic switching (The measurement range is related to the connected electrode constant)

    Temperature Measuring Range

    -10~150℃ /14~302℉

    Resistivity Display Range

    0.01Ω.cm~18MΩ.cm

    TDS Display Range

    0.000mg/L~500g/L

    Conductivity Resolution

    0.001μS/cm

    Resistivity Resolution

    0.01Ω.cm

    TDS Resolution

    0.001mg/L

    Salinity Resolution

    0.01%

    Temperature Resolution

    0.1℃/ 0.1℉

    Accuracy

    0.1% of measuring range

    Stability

    0.05% of the measuring range every 24 hours, no accumulation

    Repeatability

    Better than 0.1% of the measuring range

    Sensor diagnosis

    Screen image display

    Relay Control

    2 settable SPST relays max. load 3A/250VAC

    Analog Current Output

    2 settable 0/4~20mA active current loop output max. load 1000Ω

    Communication Method

    Two-wire RS485 interface, MODBUS RTU

    Display Screen

    128*64 LCD, adjustable backlight mode

    Configuration information

    Power failure protection, indefinite retention of parameters

    Time history/data

    Year/month/day/hour/minute/second, 14000 historical data can be recorded, and the recording interval can be set between 1 and 999 minutes

    Maintain Records

    Last 100 times

    Protection Level

    IP66

    Operating Environment

    0~60℃, relative humidity less than 95%

    Storage Environment

    -20~70℃, relative humidity less than 55%

    Shell Material

    Enhanced ABS

    Dimensions

    144*144*120mm (hole size 138*138 mm)

    Mounting Method

    Wall, pipe clamping, panel

    Electrical interface

    Three M12*1.5 Gellen heads are reserved at the back of the instrument, with a wire diameter of 3~6.5mm.

    Power Supply

    18~36V DC

    Weight

    800g

    Power Consumption

    5W



    Recommended Conductivity Sensors

    ModelMeasuring methodK-valueMeasuring rangeTemperature compensation
    ASC100Graphite 2-pole electrode10~20000μS/cmNo
    ASC200Graphite 2-pole electrode10~20000μS/cmPT or NTC
    ASC400Planar 4-pole electrode0.50~200000μS/cmNo
    ASCK12-pole conductivity cell electrode11~2000μS/cmPT or NTC
    ASCK012-pole conductivity cell electrode0.10.1~200μS/cmPT or NTC
    ASCK0012-pole conductivity cell electrode0.010.01~20μS/cmPT or NTC