Sign In | Join Free | My burrillandco.com
Home > pH ORP Sensor >

Rs485 pH Sensors With Replaceable Measuring Head For Sewage Or Drinking Water

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Rs485 pH Sensors With Replaceable Measuring Head For Sewage Or Drinking Water from wholesalers
     
    Buy cheap Rs485 pH Sensors With Replaceable Measuring Head For Sewage Or Drinking Water from wholesalers
    • Buy cheap Rs485 pH Sensors With Replaceable Measuring Head For Sewage Or Drinking Water from wholesalers
    • Buy cheap Rs485 pH Sensors With Replaceable Measuring Head For Sewage Or Drinking Water from wholesalers
    • Buy cheap Rs485 pH Sensors With Replaceable Measuring Head For Sewage Or Drinking Water from wholesalers
    • Buy cheap Rs485 pH Sensors With Replaceable Measuring Head For Sewage Or Drinking Water from wholesalers
    • Buy cheap Rs485 pH Sensors With Replaceable Measuring Head For Sewage Or Drinking Water from wholesalers

    Rs485 pH Sensors With Replaceable Measuring Head For Sewage Or Drinking Water

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : DPH890
    Certification : CE, ISO
    Payment Terms : T/T, Western Union, MoneyGram
    Supply Ability : 10000 Sets per Month
    Delivery Time : 5-25 days
    • Product Details
    • Company Profile

    Rs485 pH Sensors With Replaceable Measuring Head For Sewage Or Drinking Water


    Rs485 pH Sensors With Replaceable Measuring Head For Sewage Or Drinking Water


    The replaceable measuring head of DPH890 sensor has the following advantages:


    Economical: When the sensor head fails or is damaged, you only need to replace the head instead of buying the whole sensor. This saves the cost of repairing or replacing the sensor.


    Easy maintenance: replaceable sensor head design makes maintenance easier. You can easily remove and replace the sensor head without complicated maintenance operations.


    Reduced downtime: If a sensor head fails, you can immediately replace it with a new one instead of waiting for repairs or replacing the entire sensor. This reduces downtime during production and increases efficiency.


    Adapt to different application requirements: Different applications may require different types or specifications of sensor heads. Interchangeable sensor heads make it more flexible and convenient to choose the right head according to specific needs.


    Improved Precision and Accuracy: Over time, sensor heads may lose accuracy or precision due to the environment in which they are used. By changing the head, you can ensure that the measurement results of the sensor are always accurate and reliable.


    In short, the replaceable pH sensor measuring head can provide more economical, convenient and reliable maintenance and operation methods, making the pH measurement process more efficient and accurate.


    Specification:


    ModelDPH890DRH890
    Electrical IsolationElectrical isolated communication and power interfaces
    Measuring ObjectpHORP
    Measuring TechnologyElectrochemical glass electrodeElectrochemical platinum electrodes
    Measuring RangepH: 0~14pH TEMP: 0~50℃ORP: ±2000mV TEMP: 0~50℃
    Resolution0.01pH / 0.1℃1mV / 0.1℃
    Accuracy0.1% of the range or ±0.02pH, take the larger one; Temp: ±0.5℃

    0.1% of the range or ±2mV,

    take the larger one; Temp: ±0.5℃

    CommunicationRS485 MODBUS-RTU
    Temp UnitAutomatic Temp compensationTemp measurement
    Response TimeT90<10s
    Calibration MethodZero position calibration, slope calibration, offset calibration
    Work Pressure0~1Bar
    Sample Flow Rate0.5m/s≥flow rate≥0.001m/s
    Operating Temp0~50℃ (does not freeze)
    Storage Temp0~60℃ (does not freeze)
    Shell MaterialPOM+SS 316L or POM+Titanium alloy
    Dimension

    Diameter: 38mm length: 270 mm

    (Body:D 38mm L 270mm Head: D 27mm L 115mm)

    Mounting ThreadImmersed or piped installation (Requires mounting accessory support)
    Lead interfaceIntegral or split M16 connector
    Protection GradeIP68
    Power Supply9~24V DC
    Power Consumption0.2W
    Weight550g
    CableStandard 5 meters (other length can be customized)

    Please click the user manual of pH sensor here:

    DPH890 User manual.pdf


    Features& Advantages

    • The measuring head can be replaced, when the sensor head fails or is damaged, only the head needs to be replaced, saving the cost of repairing or replacing the sensor
    • Quick change of pH or ORP measurement unit
    • Internal storage of calibration data
    • Support offline calibration, on-site plug and play
    • Standard Modbus protocol, support access to standard industrial control system


    Aplication:

    Water treatment monitoring
    Drinking water,surface water,water quality analyze,ground water,ect.

    Industrial process monitoring and dosing control
    Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.