Sign In | Join Free | My burrillandco.com
Home > COD Analyzer >

UV254 Absorption Method RS485 COD / TOC Sensor For Waste Water Treatment

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap UV254 Absorption Method RS485 COD / TOC Sensor For Waste Water Treatment from wholesalers
     
    Buy cheap UV254 Absorption Method RS485 COD / TOC Sensor For Waste Water Treatment from wholesalers
    • Buy cheap UV254 Absorption Method RS485 COD / TOC Sensor For Waste Water Treatment from wholesalers
    • Buy cheap UV254 Absorption Method RS485 COD / TOC Sensor For Waste Water Treatment from wholesalers
    • Buy cheap UV254 Absorption Method RS485 COD / TOC Sensor For Waste Water Treatment from wholesalers
    • Buy cheap UV254 Absorption Method RS485 COD / TOC Sensor For Waste Water Treatment from wholesalers
    • Buy cheap UV254 Absorption Method RS485 COD / TOC Sensor For Waste Water Treatment from wholesalers

    UV254 Absorption Method RS485 COD / TOC Sensor For Waste Water Treatment

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : COD351L
    Certification : CE
    Price : Negotiable
    • Product Details
    • Company Profile

    UV254 Absorption Method RS485 COD / TOC Sensor For Waste Water Treatment

    UV254 Absorption Method RS485 COD/TOC sensor for waste water treatment



    UV fluorescence absorption COD sensor COD351L is a technology that uses the absorption and fluorescence characteristics of organic substances in samples to ultraviolet (UV) to measure chemical oxygen demand (COD).
    This sensor uses the ultraviolet fluorescence properties of organic substances in a sample to measure chemical oxygen demand (COD). COD is an indicator of the concentration of organic pollutants in water, which represents the amount of organic matter in water that needs to be oxidized with oxygen, thereby evaluating the degree of pollution of the water body. The advantages of UV fluorescence absorption COD sensors include rapid analysis, no reagents, real-time monitoring capability, and high sensitivity to low concentrations of organic substances. It is often used in water treatment plants, environmental monitoring, industrial process control and other fields.

    Technical Parameters

    ModelCOD351LCOD351H
    Measuring PrincipleUV254 Absorption Method
    Optical path6mm2mm
    Measuring Range

    COD: 0.75~500mg/L

    TOC: 0.3~200mg/L

    COD: 1~1500mg/L

    TOC: 0.4~600mg/L

    ResolutionCOD: 0.01mg/L TOC: 0.1mg/L
    Accuracy± 3% of the measurement + 0.5mg/L
    Related MeasurementTU: 0~300NTU accuracy: ± 5%TU: 0~1000NTU accuracy: ± 5%
    Response Time>1min
    Operating Tempe0~45℃ (does not freeze)
    Storage Temp-10~60℃
    Calibration MethodStandard solution
    Protection GradeIP68
    Working Pressure≤1bar
    Flow Ratenot depend on
    PowerDC 12V~24V
    CommunicationRS485, Modbus RTU protocol
    DimensionDiameter 60mm, length 215mm
    Lead InterfaceM16
    InstallationInvestment, 1 inch NPT pipe thread
    Shell MaterialPOM and 316L
    Power Consumption

    Normal measurement: 0.1W;

    Automatic cleaning by mechanical wiper: 3W;

    Abnormal jamming of mechanical wiper: 4.5W

    Weight720g


    Please click the user manual of Suspended Solids sensor here:


    Features

    • RS-485 output, support Modbus
    • No reagents, no pollution, environmentally friendly
    • Can measure COD, TOC, turbidity and temperature
    • Automatically compensate for turbidity interference
    • With self-cleaning brush and the maintenance cycle is longer

    Aplication:
    Water treatment plants: UV fluorescence absorption COD and TOC sensors are widely used in sewage treatment plants to monitor the content of organic substances in influent and effluent water to ensure that the discharge meets environmental protection standards.
    Environmental Monitoring: These sensors can be used for environmental monitoring such as monitoring of organic pollutants in rivers, lakes and ocean water bodies.
    Industrial process monitoring: In industrial production, especially those involving organic matter treatment, these sensors can be used to monitor water quality in real time to ensure stable production process and product quality.
    Food and beverage production: In the food and beverage industry, these sensors can be used to monitor water quality during production to ensure end product safety and compliance.
    Scientific research and laboratories: UV fluorescence absorption COD and TOC sensors are also widely used in scientific research and laboratories to analyze and study the organic content in different samples.

    Quality UV254 Absorption Method RS485 COD / TOC Sensor For Waste Water Treatment for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)